Материал: Панель АСКВ2 7016480

Внимание! Если размещение файла нарушает Ваши авторские права, то обязательно сообщите нам

Software-specific information • OPC UA server • Description of the nodes of the information model

6.7.2.1.7 Time

Path to the object directory:

Path:

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /3:Configuration/4:Time

ns

BrowseName of the parameter

Description

Service page

R

W

4

EnableNTPClient

Enables/Disables the NTP client for time synchronization.

Time

+

+

 

NTPServer1

Address of an NTP server.

Time

+

+

6.7.2.1.7.1 EnableNTPClient

Function identical to: Service page Time → "NTP client" on page 53

Path to the node (BrowsePath)

Path:

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /2:ParameterSet/4:EnableNTPClient

Alternative path (function group):

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /3:Configuration/4:Time/4:EnableNTPClient

Node attribute

NodeClass

Variable

DataType

Boolean

AccessLevel

CurrentRead, CurrentWrite

UserAccessLevel

CurrentRead, CurrentWrite

6.7.2.1.7.2 NTPServer1

Function identical to: Service page Time → NTPServer1

Path to the node (BrowsePath)

Path:

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /2:ParameterSet/4:NTPServer1

Alternative path (function group):

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /3:Configuration/4:Time/4:NTPServer1

Node attribute

NodeClass

Variable

Datentyp

String

AccessLevel

CurrentRead, CurrentWrite

UserAccessLevel

CurrentRead, CurrentWrite

96

Power Panel T50 User's manual V1.22 - Translation of the original documentation

Software-specific information • OPC UA server • Description of the nodes of the information model

6.7.2.1.8 Vnc

Path to the object directory:

Path:

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /3:Configuration/4:Vnc

ns

BrowseName of the parameter

Description

Service page

R

W

4

VNCServer

Address of the VNC server.

VNC

+

+

 

UseRfbExtension

Enables/Disables the RFB extension in VNC mode.

VNC

+

+

 

VNCLocalWindowScaling

Enables/Disables automatic scaling of the HMI application in VNC mode.

VNC

+

+

6.7.2.1.8.1 VNCServer

Function identical to: Service page VNC → "Server" on page 58

Path to the node (BrowsePath)

Path:

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /2:ParameterSet/4:VNCServer

Alternative path (function group):

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /3:Configuration/4:Vnc/4:VNCServer

Node attribute

NodeClass

Variable

Datentyp

String

AccessLevel

CurrentRead, CurrentWrite

UserAccessLevel

CurrentRead, CurrentWrite

6.7.2.1.8.2 UseRfbExtension

Function identical to: Service page VNC → "Use RFB extension" on page 59

Path to the node (BrowsePath)

Path:

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /2:ParameterSet/4:UseRfbExtension

Alternative path (function group):

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /3:Configuration/4:Vnc/4:UseRfbExtension

Node attribute

NodeClass

Variable

DataType

Boolean

AccessLevel

CurrentRead, CurrentWrite

UserAccessLevel

CurrentRead, CurrentWrite

6.7.2.1.8.3 VNCLocalWindowScaling

Function identical to: Service page VNC → "Enable local window scaling" on page 59

Path to the node (BrowsePath)

Path:

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /2:ParameterSet/4:VNCLocalWindowScaling

Alternative path (function group):

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /3:Configuration/4:Vnc/4:VNCLocalWindowScaling

Node attribute

NodeClass

Variable

DataType

Boolean

AccessLevel

CurrentRead, CurrentWrite

UserAccessLevel

CurrentRead, CurrentWrite

Power Panel T50 User's manual V1.22 - Translation of the original documentation

97

Software-specific information • OPC UA server • Description of the nodes of the information model

6.7.2.1.9 Web

Path to the object directory:

Path:

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /3:Configuration/4:Web

ns

BrowseName of the parameter

Description

Service page

R

W

4

WebServer

Address of the web server.

Web

+

+

 

VirtualKeyboardWeb

Enables/Disables the on-screen keyboard in web mode.

Web

+

+

6.7.2.1.9.1 WebServer

Function identical to: Service page Web → "Server" on page 60

Path to the node (BrowsePath)

Path:

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /2:ParameterSet/4:WebServer

Alternative path (function group):

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /3:Configuration/4:Web/4:WebServer

Node attribute

NodeClass

Variable

Datentyp

String

AccessLevel

CurrentRead, CurrentWrite

UserAccessLevel

CurrentRead, CurrentWrite

6.7.2.1.9.2 VirtualKeyboardWeb

Function identical to: Service page Web → "Virtual keyboard" on page 61

Path to the node (BrowsePath)

Path:

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /2:ParameterSet/4:VirtualKeyboardWeb

Alternative path (function group):

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /3:Configuration/4:Web/4:VirtualKeyboardWeb

Node attribute

NodeClass

Variable

DataType

Boolean

AccessLevel

CurrentRead, CurrentWrite

UserAccessLevel

CurrentRead, CurrentWrite

98

Power Panel T50 User's manual V1.22 - Translation of the original documentation

Software-specific information • OPC UA server • Description of the nodes of the information model

6.7.2.2 Control

Path to the object directory:

Path:

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /3:Control

ns

BrowseName of the method

Description

4

AwakePanel

"Wakes up" the Power Panel when the screensaver is running.

 

BuzzerDefault

Plays the buzzer with the system settings.

 

BuzzerWithPara

Plays the buzzer with the specified parameters.

 

LoadConfiguration

The Power Panel loads the last saved settings and restarts. Any changes made to the parameters are not saved and

 

 

are lost.

 

SaveConfiguration

Changes made to the parameters are saved. Method LoadConfiguration must be used to enable these stored settings

 

 

on the Power Panel.

 

SetBrightness

Changes the screen brightness from 20% to 100%.

 

SetBrightnessUnlimited

Changes the screen brightness from 0% to 100%.

 

StartUpdate

Reboots the Power Panel and start the update process.

6.7.2.2.1 AwakePanel

"Wakes up" the Power Panel when the screensaver is running.

Path to the node (BrowsePath)

Path:

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /2:MethodSet/4:AwakePanel

Alternative path (function group):

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /3:Control/4:AwakePanel

Arguments for method call

Arguments -

6.7.2.2.2 BuzzerDefault

Plays the buzzer with the system settings.

Path to the node (BrowsePath)

Path:

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /2:MethodSet/4:BuzzerDefault

Alternative path (function group):

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /3:Control/4:BuzzerDefault

Arguments for method call

Arguments -

6.7.2.2.3 BuzzerWithPara

Plays the buzzer with the specified parameters. See arguments for the method call.

Path to the node (BrowsePath)

Path:

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /2:MethodSet/4:BuzzerWithPara

Alternative path (function group):

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /3:Control/4:BuzzerWithPara

Arguments for method call

Argument

Data type

Name

Description

0

UInt32

Frequency

Frequency of the buzzer in hertz [Hz].

1

UInt32

Duration

Duration of the buzzer in milliseconds [ms].

Power Panel T50 User's manual V1.22 - Translation of the original documentation

99

Software-specific information • OPC UA server • Description of the nodes of the information model

6.7.2.2.4 LoadConfiguration

The Power Panel loads the last saved settings and restarts. Any changes made to the parameters are not saved and are lost.

Function identical to: Service page Save & Exit → Exit without saving (Button)

Path to the node (BrowsePath)

Path:

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /2:MethodSet/4:LoadConfiguration

Alternative path (function group):

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /3:Control/4:LoadConfiguration

Arguments for method call

Arguments -

6.7.2.2.5 SaveConfiguration

Changes made to the parameters are saved. Method LoadConfiguration must be used to enable these stored settings on the Power Panel.

Function identical to: Service page Save & Exit → Save changes (Button)

Path to the node (BrowsePath)

Path:

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /2:MethodSet/4:SaveConfiguration

Alternative path (function group):

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /3:Control/4:SaveConfiguration

Arguments for method call

Arguments -

6.7.2.2.6 SetBrightness

Changes the screen brightness from 20% to 100%. See arguments for the method call.

Path to the node (BrowsePath)

Path:

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /2:MethodSet/4:SetBrightness

Alternative path (function group):

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /3:Control/4:SetBrightness

Arguments for method call

Argument

Data type

Name

Description

 

 

0

UInt32

Brightness

Brightness in percent [%].

 

 

 

Range of val-

0

- 100

 

 

 

ues:

 

 

 

 

 

Scaling

0

→ 20% to 100 → 100%

6.7.2.2.7

SetBrightnessUnlimited

 

 

 

Changes the screen brightness from 0% to 100%. See arguments for the method call.

Path to the node (BrowsePath)

Path:

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /2:MethodSet/4:SetBrightnessUnlimited

Alternative path (function group):

0:Root/0:Objects/2:DeviceSet/4:PowerPanel T50 /3:Control/4:SetBrightnessUnlimited

Arguments for method call

Argument

Data type

Name

Description

 

0

UInt32

BrightnessUnlimited

Brightness in percent [%]. Values >100 are limited to 100.

 

 

 

Range of val-

0 - 100

 

 

 

ues

 

 

 

 

Scaling

No scaling: 0 → 0% to 100 → 100%

100

Power Panel T50 User's manual V1.22 - Translation of the original documentation

Источник: https://studfile.net/preview/16402365/